摘要: 研制了聚吡咯-肝素共聚膜修饰电极,并用电化学方法进行了表征。发现该修饰电极对钙离子呈Nernst响应,电极斜率为31.0 mV/pCa,线性范围是5.0×10-7~5.0×10-2 mol·L-1,可用于儿童发样中钙的测定,结果满意,还测定了该修饰电极对其他阳离子的电位选择系数。
关键词: 聚吡咯 肝素 Ca2+ 化学修饰电极
基金项目: 
Abstract: The fabrication of a PPy-Heparin composite film modified electrode in pyrrole with coexistence of heparin is described. The characteristics of the PPy-Heparin modified electrode was studied with electrochemical methods. A linear response was observed for Ca2+ in the concentration range of 5.0×10-7 to 5.0×10-2 mol·L-1 with a slop of 31.0 mV/pCa. The influences of the activities of other cations (K+, Mg2+, Zn2+, Co2+, Cu2+ and Pb2+) in the solution were studied. The PPy-Heparin modified electrode was easy to make and very stable, which can be used for the detection of calcium in children′s hair. The results of detection was satisfactory.